Clay tile, an iron damper and old brick: the chimney in an older sale

Book a Level 2 for a sale

The parts of an older chimney

A chimney on a house put up before 1980 is rarely one thing. Inside it, usually, is a column of square clay tiles stacked end to end: the flue, which carries the smoke. Just above the firebox sits an iron or steel plate on a pivot: the damper. Around both is brick laid in mortar, finished at the top with a cement slab and, on the lucky ones, a cap. Each of these wears out on its own schedule, and any one of them can be the reason a fireplace smokes, smells or refuses to pull.

A sale is often the first time in decades those parts get looked at by anyone other than the owner. The general home inspector notes that a fireplace exists and suggests a specialist. A Level 2 goes through each part in turn, with a camera inside the flue, and writes down what it found in words a buyer, a seller and both agents can follow.

  • Clay tile flue: joints, cracks, missing pieces, soot and glaze
  • Damper: whether it opens all the way, shuts all the way and is still attached
  • Brick and mortar: washed out joints, flaking faces, lean
  • Top of the stack: the cement slab, the cap and the metal where it meets the roof

What a Level 2 looks at in each part

Inside the flue we run a camera from the smoke chamber to the top and record the tile joints, any offset or gap between tiles, cracks across a tile, and how much soot or tar is stuck to the walls. Gaps between old tiles are common after decades of heat and a few earthquakes. They matter twice over: they let heat reach the brick, and they leak the pull that keeps smoke moving upward.

At the damper we check that the plate swings fully open and closes snugly, and that rust has not eaten the pivot or the frame. On the brick, from the roof and the attic, we look for joints that have washed out, faces that have flaked off and any gap opening between the chimney and the house. We also note what affects draft: flue size against the fireplace opening, stack height against the roofline, and whether the top is open to wind.

Why draft belongs in a sale report

Someone moving into an older house will usually light the fireplace in the first winter. If it smokes, the first question is whether it ever worked. A report that says the flue suits the opening, the damper moves freely and the top is covered settles that before closing. A report that says the flue is undersized, or the tile is gapped, gives both sides a known item to deal with, priced on this site's figures where one applies.

For a seller, having the report early turns the chimney into a known line in the disclosure packet instead of a surprise from the other side. Across Lynwood and the towns around it we see plenty of chimneys from before 1980, and the ones that cause trouble in escrow are nearly always the ones nobody looked at first.

What the sale inspection costs

One fixed figure for the inspection. Repairs it turns up appear as separate items.

Camera inspection for a sale, written up with photos
$385
Visual check of the reachable parts only
$54

A sale calls for the camera inspection. The visual check suits a chimney you already own and burn the same way each season.

Questions about older chimneys in a sale

The house is from the 1950s. Is a clay tile flue a problem in itself?

No. Clay tile is a sound material, and plenty of old flues are in fine shape. What we look for is what time has done to it: gaps at the joints, cracks across tiles and pieces that have dropped out. The report says which of those, if any, we found.

Can the inspection tell us whether the fireplace will smoke?

It checks the things that make a fireplace smoke: whether the flue suits the opening, whether the damper opens fully, whether the passage is narrowed and whether the top is exposed to wind. If any of those points to a draft problem, the report says so plainly.

Who receives the report?

Whoever books it, and anyone they ask us to include, such as the agents on each side. Everyone gets the same document.

What if the damper is rusted shut?

We photograph it and note it. The usual fixes are freeing and resetting the old plate or adding a lid style damper at the top of the flue. Both are measured on the visit and given a written figure.

The fireplace was converted to gas logs. Does it still need the camera?

Yes. Gas logs still send their exhaust up the old flue, so the tile has to be whole, the passage open and the damper held partly open. The camera inspection checks all three.

Will it show cracks from past earthquakes?

The camera shows cracks and offsets in the tile whatever caused them, and from the roof and the attic we look for gaps between the chimney and the house. We describe what we see and do not guess at which quake caused it.

Selling or buying an older house in Lynwood?

Use the contact page to send the address and how many fireplaces it has. We call back to arrange the camera inspection and confirm who receives the report.

Call (323) 524-3932